GELLHORN PESSARY
Short Stem / Standard Stem



Key Features:
Made from medical-grade, clear silicone that is flexible and latex-free, ensuring maximum safety and comfort for patients. |
Flat disc with a central stem, available in short and standard stem options, designed for secure fit and effective support. |
Wide range of sizes options with Outer diameters from 38 mm to 95 mm (sizes 0–9). |
Provides effective support for severe pelvic organ prolapse, including third-degree prolapse or procidentia, improving patient quality of life. |
Durable design allows long-term use, reducing replacement costs and enhance patient experience. |
Works best for patients with a capacious vagina and intact perineum, ensuring a stable and comfortable experience. |
Latex free, does not contain metal and CT/MRI Safe |
Replace every 5 years of use |
Individually packed in easy to open box |
The Balance Gellhorn Pessary is a flexible medical-grade clear silicone device designed to fit inside the vagina to support the uterus, bladder, and/or rectum. It is primarily used for managing third-degree prolapse or procidentia. The cervix rests behind the flat base of the pessary, with only the stem visible at the vaginal entrance during a Valsalva manoeuvre. It requires a relatively capacious vagina and an intact perineum.
Product Listings

Size | Diameter | PIP Code Short Stem |
PIP Code Standard Stem |
---|---|---|---|
0 | 38mm | 4344974 | 4345070 |
1 | 45mm | 4344982 | 4345088 |
2 | 51mm | 4344990 | 4345096 |
3 | 57mm | 4345005 | 4345112 |
4 | 64mm | 4345013 | 4345120 |
5 | 70mm | 4345021 | 4345138 |
6 | 76mm | 4345039 | 4345146 |
7 | 83mm | 4345047 | 4345153 |
8 | 89mm | 4345054 | 4345161 |
9 | 95mm | 4345062 | 4345179 |
The Flexible Gellhorn Pessary is widely used to provide effective support for third-degree prolapse or procidentia. During use, the cervix rests behind the flat base of the pessary, with only the stem visible at the vaginal opening when the patient performs a Valsalva maneuver. This device is best suited for patients with a spacious vaginal canal and an intact perineum.
Prior to unpacking, ensure that the package remains unopened and pessary remains sealed within the provided medical sachet in the box. Prior to utilizing the device, ensure the following:
If any of the aforementioned defects are identified, DO NOT USE THE DEVICE and promptly REPLACE IT.
Document
See the below leaflet for instructions for use and care. Failure to follow Instructions for Use may affect the product performance.
Instructions for useDispose of, in case of replacement or breakage, in accordance with local waste disposal regulations.
There are no toxic substances present in the source material.